Catalogue
Showing 1–150 of 324 results
-
-
-
-
-
-
-
-
12DV36
- Up to 7,800 kW (continuous rating)
- Medium-speed (600-750 rpm)
- IMO Tier III compliant (EGR or SCR)
- 2-stage turbocharging
-
12DV36 genset
-
Up to 7594 kWe @ 50 Hz
- Up to 7290 kWe @ 60 Hz
- Medium-speed (600-750 rpm)
- IMO Tier III compliant (EGR or SCR)
-
-
12DZC
- Up to 2,652 kWm (continuous rating)
- Up to 3,000 kWm for special applications
- SMART mechanical
- IMO Tier III compliant *
-
12DZC genset
-
Up to 2,546 kWe @ 50 Hz
- Up to 2,292 kWe @ 60 Hz
- Medium-speed (720-1000 rpm)
- SMART mechanical
-
-
12DZD MeOH
- Up to 2,652 kWm / 3,610 HP (continuous rating)
- Up to 70% methanol - 30% (bio)diesel/HVO
- Low Pressure Fuel Injection (< 10 bar)
- Compact Fuel Preparation Compartment
-
12DZD MeOH genset
-
Up to 2,519 kWe / 3,149 kVA @ 50 Hz (continuous rating)
- Up to 2,267 kWe / 2,834 kVA @ 60 Hz (continuous rating)
- Up to 70% methanol - 30% (bio)diesel/HVO
- Low Pressure Fuel Injection (< 10 bar)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
16DV36
- Up to 10,400 kWm (continuous rating)
- Medium-speed (600-750 rpm)
- IMO Tier III compliant (EGR or SCR)
- 2-stage turbocharging
-
16DV36 genset
-
Up to 10,126 kWe @ 50 Hz
- Up to 9,720 kWe @ 60 Hz
- Medium-speed (600-750 rpm)
- IMO Tier III compliant (EGR or SCR)
-
-
16DZC genset
-
Up to 3,395 kWe @ 50 Hz
- Up to 3,057 kWe @ 60 Hz
- Medium-speed (720-1000 rpm)
- SMART mechanical
-
-
16DZD MeOH
- Up to 3,536 kWm / 4,810 HP (continuous rating)
- Up to 70% methanol - 30% (bio)diesel/HVO
- Low Pressure Fuel Injection (< 10 bar)
- Compact Fuel Preparation Compartment
-
16DZD MeOH genset
-
Up to 3,359 kWe / 4,199 kVA @ 50 Hz (continuous rating)
- Up to 3,023 kWe / 3,779 kVA @ 60 Hz (continuous rating)
- Up to 70% methanol - 30% (bio)diesel/HVO
- Low Pressure Fuel Injection (< 10 bar)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
6DL36
- Up to 3,955 kWm (continuous rating)
- Medium-speed (600-750 rpm)
- IMO Tier III compliant (EGR or SCR)
- 2-stage turbocharging
-
6DL36 genset
-
Up to 3,797 kWe @ 50 Hz
- Up to 3,645 kWe @ 60 Hz
- Medium-speed (600-750 rpm)
- IMO Tier III compliant (EGR or SCR)
-
-
6DZC
- Up to 1,326 kWm (continuous rating)
- Up to 1,500 kWm for special applications
- SMART mechanical
- IMO Tier III compliant *
-
6DZC genset
-
Up to 1,273 kWe @ 50 Hz
- Up to 1,146 kWe @ 60 Hz
- Medium-speed (720-1000 rpm)
- SMART mechanical
-
-
6DZD MeOH
- Up to 1,326 kWm / 1,800 HP (continuous rating)
- Up to 70% methanol - 30% (bio)diesel/HVO
- Low Pressure Fuel Injection (< 10 bar)
- Compact Fuel Preparation Compartment
-
6DZD MeOH genset
-
Up to 1,260 kWe / 1,575 kVA @ 50 Hz (continuous rating)
- Up to 1,134 kWe / 1,417 kVA @ 60 Hz (continuous rating)
- Up to 70% methanol - 30% (bio)diesel/HVO
- Low Pressure Fuel Injection (< 10 bar)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
8DL36
- Up to 5,200 kW (continuous rating)
- Medium-speed (600-750 rpm)
- IMO Tier III compliant (EGR or SCR)
- 2-stage turbocharging
-
8DL36 genset
-
Up to 5,063 kWe @ 50 Hz
- Up to 4,860 kWe @ 60 Hz
- Medium-speed (600-750 rpm)
- IMO Tier III compliant (EGR or SCR)
-
-
8DZC
- Up to 1,768 kWm (continuous rating)
- Up to 2,000 kWm for special applications
- SMART Mechanical
- IMO Tier III comliant *
-
8DZC genset
-
Up to 1,697 kWe @ 50 Hz
- Up to 1,528 kWe @ 60 Hz
- Medium-speed (720-1000 rpm)
- SMART mechanical
-
-
8DZD MeOH
- Up to 1,768 kWm / 2,410 HP (continuous rating)
- Up to 70% methanol - 30% (bio)diesel/HVO
- Low Pressure Fuel Injection (< 10 bar)
- Compact Fuel Preparation Compartment
-
8DZD MeOH genset
-
Up to 1,680 kWe / 2,100 kVA @ 50 Hz (continuous rating)
- Up to 1,512 kWe / 1,890 kVA @ 60 Hz (continuous rating)
- Up to 70% methanol - 30% (bio)diesel/HVO
- Low Pressure Fuel Injection (< 10 bar)
-
-
-
-
-
-
-
-
BeHydro 12DZ H2
- Up to 2,000 kWm / 2,720 HP (continuous rating)
- 100% hydrogen
- Meets Gas Safe engine room standards
- Can run on less purified hydrogen
-
BeHydro 12DZ H2 genset
- Up to 1,900 kWe / 2,375 kVA @ 50 Hz (continuous rating)
- Up to 1,710 kWe / 2,138 kVA @ 60 Hz (continuous rating)
- 100% hydrogen (ZERO emission)
- Can run on less purified hydrogen
-
BeHydro 12DZD H2
- Up to 2,000 kWm / 2,720 HP (continuous rating)
- Up to 85% hydrogen - 15% (bio)diesel/HVO
- Meets Gas Safe engine room standards
- Can run on less purified hydrogen
-
BeHydro 12DZD H2 genset
-
Up to 1,900 kWe / 2,375 kVA @ 50 Hz (continuous rating)
- Up to 1,710 kWe / 2,138 kVA @ 60 Hz (continuous rating)
- Up to 85% hydrogen - 15% (bio)diesel/HVO
- Can run on less purified hydrogen
-
-
BeHydro 16DZ H2
- Up to 2,670 kWm / 3,630 HP (continuous rating)
- 100% hydrogen
- Meets Gas Safe engine room standards
- Can run on less purified hydrogen
-
BeHydro 16DZ H2 genset
- Up to 2,537 kWe / 3,171 kVA @ 50 Hz (continuous rating)
- Up to 2,280 kWe / 2,850 kVA @ 60 Hz (continuous rating)
- 100% hydrogen (ZERO emission)
- Can run on less purified hydrogen
-
BeHydro 16DZD H2
- Up to 2,670 kWm / 3,630 HP (continuous rating)
- Up to 85% hydrogen - 15% (bio)diesel/HVO
- Meets Gas Safe engine room standards
- Can run on less purified hydrogen
-
BeHydro 16DZD H2 genset
-
Up to 2,537 kWe / 3,171 kVA @ 50 Hz (continuous rating)
- Up to 2,280 kWe / 2,850 kVA @ 60 Hz (continuous rating)
- Up to 85% hydrogen - 15% (bio)diesel/HVO
- Can run on less purified hydrogen
-
-
BeHydro 6DZ H2
- Up to 1,000 kWm / 1,360 HP (continuous rating)
- 100% hydrogen
- Meets Gas Safe engine room standards
- Can run on less purified hydrogen
-
BeHydro 6DZ H2 genset
- Up to 950 kWe / 1,188 kVA @ 50 Hz (continuous rating)
- Up to 855 kWe / 1,069 kVA @ 60 Hz (continuous rating)
- 100% hydrogen (ZERO emission)
- Can run on less purified hydrogen
-
BeHydro 6DZD H2
- Up to 1,000 kWm / 1,360 HP (continuous rating)
- Up to 85% hydrogen - 15% (bio)diesel/HVO
- Meets Gas Safe engine room standards
- Can run on less purified hydrogen
-
BeHydro 6DZD H2 genset
-
Up to 950 kWe / 1,188 kVA @ 50 Hz (continuous rating)
- Up to 855 kWe / 1,069 kVA @ 60 Hz (continuous rating)
- Up to 85% hydrogen - 15% (bio)diesel/HVO
- Can run on less purified hydrogen
-
-
BeHydro 8DZ H2
- Up to 1,335 kWm / 1,810 HP (continuous rating)
- 100% hydrogen
- Meets Gas Safe engine room standards
- Can run on less purified hydrogen
-
BeHydro 8DZ H2 genset
- Up to 1,268 kWe / 1,585 kVA @ 50 Hz (continuous rating)
- Up to 1,140 kWe / 1,425 kVA @ 60 Hz (continuous rating)
- 100% hydrogen (ZERO emission)
- Can run on less purified hydrogen
-
BeHydro 8DZD H2
- Up to 1,330 kWm / 1,810 HP (continuous rating)
- Up to 85% hydrogen - 15% (bio)diesel/HVO
- Meets Gas Safe engine room standards
- Can run on less purified hydrogen
-
BeHydro 8DZD H2 genset
-
Up to 1,268 kWe / 1,585 kVA @ 50 Hz (continuous rating)
- Up to 1,140 kWe / 1,425 kVA @ 60 Hz (continuous rating)
- Up to 85% hydrogen - 15% (bio)diesel/HVO
- Can run on less purified hydrogen
-
-
-
-
-
-